Skip to main content

Downlink — send data to a multicast group

According to the v0.17 description, the command queues a data frame for sending to a multicast group. In the current ONS version it does not: the server validates the request but does not queue the frame and does not respond to a valid request.

Request and response: multicast_data_req → no response; on error — a message with the same cmd: multicast_data_req.
Access: high access level token only. With a low access level token the server responds with error 1.

Current ONS version

Differences from the v0.17 description:

  • The command is not executed: the frame is not queued and does not go on air.
  • The server does not respond to a valid request. The multicast_data_resp message with dataId does not exist.
  • On error the server sends a message with cmd: multicast_data_req, without operation_id and without error_text.

Request​

Fields not marked as required may be omitted. The server only validates their format.

FieldTypeDescription
cmdstringmulticast_data_req
operation_idstringAny string; the server does not return it in the response
datastringRequired. Payload in hex
multicast_euistringGroup EUI, 16 hex characters
multicast_addrstringGroup address, 8 hex characters
gatewayEuistringGateway EUI, 16 hex characters
fportuint8Application port, 0–255. Default 2
fcntuint16Frame counter, 0–65535. Default 0
{
"cmd": "multicast_data_req",
"operation_id": "xyz",
"multicast_eui": "7DA50BE8C74CE6DC",
"fport": 2,
"data": "FFFFFFFFFFFF"
}

Response​

There is no response to a valid request. A message arrives only on error:

FieldTypeDescription
cmdstringmulticast_data_req
statusuint82 — error
error_codeuint8Error code, see below
{
"cmd": "multicast_data_req",
"status": 2,
"error_code": 3
}

Errors​

error_codeerror_textWhat happened
1—The request came with a low access level token
3—Invalid data: data is missing or is not hex; multicast_eui or gatewayEui is not 16 hex characters; multicast_addr is not 8; fport is not 0–255; fcnt is not 0–65535